    I had the opposite problem, I brought a soldering iron from Europe to Canada, and despite using a step up transformer, it just couldn’t get hot enough to melt the solder!

    • aname
      link
      fedilink
      English
      arrow-up
      26
      ·
      1 day ago

      You should have used 200% duty cycle

      • Rivalarrival@lemmy.today
        link
        fedilink
        English
        arrow-up
        19
        ·
        1 day ago

        Splice on a second plug, so you can use two outlets at the same time.

        (/s, mostly… this can actually work, if you can find two outlets on opposite phases.)

        • Trail@lemmy.world
          link
          fedilink
          English
          arrow-up
          4
          ·
          1 day ago

          But it wouldn’t be 200%, it would be something like 170% power assuming 3 phases, right. Too lazy to do the math.

          • aname
            link
            fedilink
            English
            arrow-up
            1
            ·
            14 hours ago

            US has two phase power in residential households

            • Rivalarrival@lemmy.today
              link
              fedilink
              English
              arrow-up
              1
              ·
              5 hours ago

              Split phase, not two phase.

              Two-Phase has two legs, 90 degrees apart. When one phase is at maximum amplitude the other phase will be at zero.

              Split Phase is 180 degrees apart. When one leg is at maximum positive amplitude, the other will be at maximum negative amplitude. When either is crossing zero, the other is also crossing zero, in the opposite direction.

          • Zink@programming.dev
            link
            fedilink
            English
            arrow-up
            4
            ·
            22 hours ago

            Like others said, we do split phase to residential in the US. So the funny thing is, for all of our wimpy 120V outlets, our homes literally have 240V service. We just don’t wire it to the outlets because you know, standards and fire.

            I just made dinner on my induction stove that’s connected to 240V and it’s wonderfully powerful. We use special outlets for 240V, and it’s typically for the major appliances you might expect, if they are electric versions. Oven/stove, clothes dryer, water heater, heat pump, air conditioner, EV charger, etc.

          • Rivalarrival@lemmy.today
            link
            fedilink
            English
            arrow-up
            7
            ·
            edit-2
            20 hours ago

            You’re correct, phase-to-phase is 173.2% of the phase-to-neutral voltage in 3-phase “Wye” service.

            But that’s not what consumers (typically) use in North America. We don’t bring three phase to the home.

            Our single-phase final distribution transformers have a center tap on the secondary coil, bonded to neutral. So, one side of the coil provides a 120v leg with respect to that neutral, and the other side provides an opposing leg, 180° from the first, and 120v with respect to that same neutral. Most of our appliances use leg-to-neutral, 120v. But leg-to-leg is 240v.

            (Commercial and industrial facilities can get a wide variety of voltages in single or three phase, and we do have some actual, 2-phase generators and customers: the phases are 90° apart rather than 120° or 180°)

            • evidences@lemmy.world
              link
              fedilink
              English
              arrow-up
              3
              ·
              24 hours ago

              The technology connections video talking about 240v power mentioned some apartment buildings having 208v because they’re bringing in two phases instead of center tapping or whatever. So their comment could be right in the correct locations i think.

              I’m clearly no sparky.

                • Riprif@lemmy.world
                  link
                  fedilink
                  English
                  arrow-up
                  2
                  ·
                  18 hours ago

                  And lots of things meant to run on 240 are dual labeled 208/240. If it’s a motor it will end up running a little hotter, if it’s a heater it will end up a little colder.